Radical Monitorのメーカーや取扱い企業、製品情報、参考価格、ランキングをまとめています。
イプロスは、 製造業 BtoB における情報を集めた国内最大級の技術データベースサイトです。

Radical Monitor - メーカー・企業と業務用製品 | イプロスものづくり

Radical Monitorの製品一覧

1~2 件を表示 / 全 2 件

表示件数

Radimo Radical Monitor <Opposing Type Radical Monitor DP Type>

This is the world's first ultra-compact radical absolute density measurement device that can be used in processes.

The Radimo Radical Monitor <Opposing Type Radical Monitor DP Type> is a monitoring device that measures atomic radicals in the gas phase generated during etching, surface treatment, and thin film production, enabling feedback into the process. It is the world's first ultra-compact radical absolute density measurement device that can be used in processes. It measures atoms present in the ground state in plasma using absorption spectroscopy, allowing for the selection of the optimal structure based on the measurement target and purpose. The measurement software is equipped with the latest calibration results from research conducted at Nagoya University’s Hori Laboratory. For more details, please contact us or refer to the catalog.

  • Other inspection equipment and devices
  • Radical Monitor

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録

F-RadiMo Radical Monitor "SP Type-RadiMo"

Absolute density measurement of fluorine radicals using vacuum ultraviolet absorption spectroscopy! Various applications for measurement as well.

The "SP-type RadiMo" is a device that can measure the absolute density of fluorine radicals in their ground state using absorption spectroscopy. The spectrum of the probe light emitted from the light source is calibrated with high precision. Additionally, it can measure in both emitting and non-emitting plasma. The F-RadiMo can be installed on the port of a process device for measurement. 【Features】 ■ Measurement of the absolute density of fluorine radicals ■ Capable of measuring in both emitting and non-emitting plasma ■ No calibration required for absolute density calculation ■ F-RadiMo can be installed on the port of a process device for measurement ■ Various measurement applications *For more details, please refer to the PDF document or feel free to contact us.

  • Other measurement, recording and measuring instruments
  • Other electronic measuring instruments
  • Radical Monitor

ブックマークに追加いたしました

ブックマーク一覧

ブックマークを削除いたしました

ブックマーク一覧

これ以上ブックマークできません

会員登録すると、ブックマークできる件数が増えて、ラベルをつけて整理することもできます

無料会員登録